5. HOW TO PROCESS TUBING Caution Before Connecting Tubes Tightly (1) Apply a sealing cap or water-proof tape to prevent dust or The liquid tubing side is connected by a flare nut, and the gas water from entering the tubes before they are used. tubing side is connected by brazing. (2) Be sure to apply refrigerant lubricant (ether oil) to the inside of the flare nut before making piping connections. This is effective for reducing gas leaks. (Fig. 5-4) 5-1. Connecting the Refrigerant Tubing Use of the Flaring Method Many of conventional split system air conditioners employ the flaring method to connect refrigerant tubes that run between indoor and outdoor units. In this method, the copper tubes are Apply refrigerant lubricant. flared at each end and connected with flare nuts. Fig. 5-4 Flaring Procedure with a Flare Tool (3) For proper connection, align the union tube and flare tube (1) Cut the copper tube to the required length with a tube straight with each other, then screw on the flare nut lightly...